Support
Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation (ISSN:1671-7104 )is a peer-reviewed scopus indexed journal. This journal is a national-level technical publication approved by the Science and Technology Commission and the Ministry of Health and officially published at home and abroad. It has a history of more than 40 years.
There are common problems in realistic medical consumables management such as inconsistent material names, irregular billing, extensive management of sub-warehouse. It is necessary to use information systems to achieve full-process, refined, traceable management of medical consumables. A cloud-based information management system of medical consumables is introduced, which connects consumables access, acceptance, consumption and settlement by matching UDI code, charge code and medical insurance code. The system connects to external systems such as charging system. The system realizes traceab
To characterize the silver in chitosan antibacterial gel, and to establish a method for the determination of silver content in samples. The silver in the samples was analysed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). Microwave digestion was adopted to digest the chitosan antibacterial gel, and then the content of silver was determined by flame atomic absorption spectrometry. The analysises showed that the particle size of silver in chitosan antibacterial gel was about 150~ 200 nm.
In daily life, the movement of the neck will cause certain deformation of the blood vessel and the stent. This study explores the quantitative influence of the torsion deformation of the blood vessel on the mechanical properties of the stent. In the finite element simulation software Abaqus, the numerical simulation of the crimping and releasing process of the stent, the numerical simulation of the torsion process of the blood vessel with the stent, and the numerical simulation of the pressure loading process of the outer wall of the blood vessel were carried out. After the stent was implan
The high incidence of cardiovascular diseases is a serious threat to human health, and endovascular surgery has become the standard treatment for most interventional cardiovascular diseases. The robotassisted endovascular surgery system further enhances surgeons' ability to perform minimally invasive endovascular procedures in interventional cardiology. This study presents a new robotic technique for coronary intervention from the perspective of clinical application. Aiming at clinical application scenarios, this scheme proposed an intuitive guide wire catheter mechanism design, which a
Aiming at the medical service robot used in the indoor environment, this study proposes a method to test the pose accuracy of its working surface based on the binocular vision system. This method uses a binocular vision coordinate system to measure targets fixed on the working surface of the service robot, aligns the measurement system with the robot base coordinate system through the nonlinear least squares method, and integrates the multi-eye image data to achieve the accuracy test of the working surface. Finally, the vision test program was tested and verified on a mobile service robot m